Design Criteria Summary
External Walls:
320mm x 2400mm x 1200mm Galvanised steel structural wire frame with 280mm EPS insulation encased with 20mm waterproof render
Internal Walls:
(a) 120mm width galvanised structural steel wire frame with 80mm EPS (b) 170mm width galvanised structural steel wire frame with 150mm EPS encased with 20mm waterproof render
Floor Sections:
300mm deep x 4/5/6m length x 1.2m width with galvanised structural steel wire frame with 130mm EPS with steel reinforced steel bars in 120mm deep sections
Roof Sections:
170mm with galvanised structural steel wire frame with 130mm EPS encased in 20mm waterproof render
Solar panels/tiles:
To be added to South facing roof
Ceiling System:
150mm deep x 4/5/6m length x 1.2m width with galvanised structural steel wire frame with 130mm EPS with steel reinforced steel bars in 150mm deep sections. Converted tile or metal or green roof can be fixed to North facing roof
Panel to Panel Fixing:
Proprietary metal clips at 300mm centres with 50x50 reinforcing mesh fixed at all panel junctions or corners
Panel to Foundation Fixing:
Starter box cast into foundation slab mechanically fixed and reinforced to each wall panel at 300mm centres in accordance with structural requirements
Foundations:
6 Designs have been configured to cover all requirements across the UK under LANTAC approval. Pile foundations can be adopted to minimise site disurbances
Air Tightness:
Designed to 2M3/M2Ph at 50Pa
Insulation:
EPS Graphite Lambda value of 0.029W/m2K
Walls:
U-Value of 0.11W/m2K
Passiv Haus:
Exceeds standard
Code 6 Sustainable Housing:
Exceeds standard
Rainwater Harvesting:
Meets future water regulations
Low Voltage Power System:
Incorporates a low voltage system generated from PV roof system